カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 16WC-3
Rated Flow 39.63 gpm 150 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1-1/2 in. 38 mm
Valve Installation Torque 74 lbf-ft 100 Nm
Weight 0.69 lbs 0.31 kg
This is a pilot-to-open check valve. When pressure at port 2 exceeds the spring bias pressure, the poppet is pushed from its seat and allowed from port 2 to port 1. When sufficient pilot pressure is present at port 3, the pilot piston operates to push the poppet, flow is allowed from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 affects pilot-to-open pressure on a 1:1 ratio. Hardening processes and precision machining for long life and low leakage.

  • This valve can prevent the drifting of loads and securely locks pressurized loads, also provides protection to a pipe rupture or hose break.
  • Internal components are made of high-quality materials, processed heat treatment and precision grinding to achieve excellent wear resistance and protection against contamination for long-lasting durability.
  • Virtually leak-free. If the valve causes the load to drift, the seat may be damaged by contamination. Please replace the valve immediately.
  • Pilot-to-open check valves are not intended to be used as motion control valves. If motion control is required in a circuit, please choose counterbalance valves.
  • Industry common cavity.
  • This valve is suitable for mounting in regenerative circuits or for controlling motors or cylinders.
  • Available bias springs for back pressure applications flexibility.
  • Consider using a check valve instead of a counterbalance valve if overrunning loads or controlled release speed are not critical in the application.
  • Based on the same flow rate, installation position, flow path, and cavity, three-port pilot-to-open check valves and three-port counterbalance valves are interchangeable. However, please note that there are functional differences and variations in external dimensions between them.
  • External components are WINNERcoat® Zinc-Nickel Plating for 1000 hours salt spray test according to DIN EN ISO 9227. Ordering code with letter "P" at the end is stainless steel external components. 
  • Winner guarantees that all products performance a 100% functional test before shipment.
逆止弁性能曲線 (typical pressure drop performance curve) for CO16WC30 pilot-to-open check valve, free flow from port 2 to port 1, showing pressure and flow characteristics