Cartridge Valves
FILTER
Cartridge Valves
| Symbol | Description | ||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Pilot-to-open, port 2 to port 3 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-08W-X-Y-Z | 30 | 350 | 08W-3 |
| CO-10W-X-Y-Z | 30 | 240 | 10W-3 | ||||||
| CO-22M-3C-Y-Z | 30 | 315 | 22M-3 | ||||||
|
Pilot-to-open, port 2 to port 3, pilot ratio 2:1 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-08W-X-Y-Z | 30 | 240 | 08W-3 |
|
Pilot-to-open, port 2 to port 3, pilot ratio 3:1 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-11A-38-Y-Z | 60 | 350 | 11A-3 |
|
Vented, atmospherically referenced, pilot-to-open | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CK-11A-3C-Y-Z | 60 | 350 | 11A-3 |
| CK-2A-3C-Y-Z | 120 | 350 | 2A-3 | ||||||
| CK-17A-3C-Y-Z | 240 | 350 | 17A-3 | ||||||
| CK-19A-3C-Y-Z | 480 | 350 | 19A-3 | ||||||
|
Vented, pilot-to-open, sealed pilot piston, pilot ratio 3:1 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CK-21A-4C-Y-Z | 60 | 350 | 21A-4 |
| CK-22A-4C-Y-Z | 120 | 350 | 22A-4 | ||||||
| CK-23A-4C-Y-Z | 240 | 350 | 23A-4 | ||||||
| CK-24A-4C-Y-Z | 480 | 350 | 24A-4 | ||||||
|
Vented, pilot-to-open, pilot ratio 3:1 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CK-21AS-40-Y-Z | 60 | 350 | 21AS-4 |
|
Pilot-to-open check valve with adjustment screw | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-08W-X-Y-Z | 30 | 240 | 08W-3 |
|
Insert-type, pilot-to-open | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-163A-X-Y-Z | 30 | 350 | 163A-3 |
|
Pilot-to-open check valve with external pilot port | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-11A-X-Y-Z | 60 | 350 | 11A-3 |
|
Pilot-to-open check valve with external pilot port, sealed pilot and stem seal | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-2A-3F-Y-Z | 120 | 350 | 2A-3 |
| CO-17A-3F-Y-Z | 240 | 350 | 17A-3 | ||||||
| CO-19A-3F-Y-Z | 480 | 350 | 19A-3 | ||||||
|
Free flow port 2 to port 1, port 3 blocked | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CV-11A-21-Y-Z | 60 | 350 | 11A-3 |
| CV-2A-21-Y-Z | 120 | 350 | 2A-3 | ||||||
| CV-17A-21-Y-Z | 240 | 350 | 17A-3 | ||||||
| CV-19A-21-Y-Z | 480 | 350 | 19A-3 | ||||||
|
Free flow port 1 to port 2, port 3 blocked | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CV-11A-20-Y-Z | 80 | 350 | 11A-3 |
| CV-2A-20-Y-Z | 160 | 350 | 2A-3 | ||||||
|
Dual pilot to open | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CO-10W-43-Y-Z | 30 | 240 | 10W-4 |
|
Pilot ratio 2.3 : 1 (with sealed pilot), semi-restrictive, non-vented, fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-3B-Y-Z40 | 40 | 350 | 11A-3 |
|
Pilot ratio 4.5 : 1 (with sealed pilot), semi-restrictive, non-vented, fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-3D-Y-Z40 | 40 | 350 | 11A-3 |
|
Pilot ratio 3 : 1, fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-33-Y-Z | 60 | 280 | 11A-3 |
| CBA-10WC-33-Y-Z | 60 | 350 | 10WC-3 | ||||||
|
Pilot ratio 4.5 : 1, fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-34-Y-Z | 60 | 350 | 11A-3 |
|
Pilot ratio 4.5 : 1 (with sealed pilot), fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-3D-Y-Z | 60 | 350 | 11A-3 |
| CB-2A-3D-Y-N | 120 | 350 | 2A-3 | ||||||
| CB-17A-3D-Y-N | 240 | 350 | 17A-3 | ||||||
| CB-19A-3D-Y-N | 480 | 350 | 19A-3 | ||||||
|
Pilot ratio 10 : 1, fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-30-Y-Z | 60 | 350 | 11A-3 |
|
Pilot ratio 16 : 1 (with sealed pilot), fixed setting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CB-11A-3P-Y-Z | 60 | 350 | 11A-3 |