Symbol | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
Hose burst protection valve, insert-type with female-female sleeve | Main Code | Flow(l/min) | Pressure(bar) | Cavity | MEG02BG02B-HBZ | 4-25 | 350 | - |
MEG03BG03B-HBZ | 6-50 | 350 | - | ||||||
MEG04BG04B-HBZ | 16-80 | 350 | - | ||||||
MEG06BG06B-HBZ | 25-150 | 350 | - | ||||||
![]() |
Hose burst protection valve, insert-type with male-female sleeve | Main Code | Flow(l/min) | Pressure(bar) | Cavity | MEG02BG02A-HBZ | 4-25 | 350 | - |
MEG03BG03A-HBZ | 6-50 | 350 | - | ||||||
MEG04BG04A-HBZ | 16-80 | 350 | - | ||||||
MEG06BG06A-HBZ | 25-150 | 350 | - | ||||||
![]() |
Spool type, normally closed, modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-11A-36-Y-Z | 6 | 350 | 11A-3 |
![]() |
Bypass/restrictive, priority modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-10W-40-Y-Z | 38 | 240 | 10W-4 |
LR-12W-40-Y-Z | 80 | 240 | 12W-4 | ||||||
LR-16W-40-Y-Z | 100 | 240 | 16W-4 | ||||||
![]() |
Spool type, normally closed modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-12WS-30-Y-Z | 150 | 350 | 12WS-3 |
![]() |
Unbalanced poppet, pilot-to-close, spring biased closed, with position switch | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LOS-2A-3C-Y-Z | 200 | 350 | 2A-3 |
![]() |
Inverse direct-acting, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRA-8A-2D-Y-Z-74 | 1 | 350 | 8A-2 |
PRA-8A-2C-Y-Z | 1 | 350 | 8A-2 | ||||||
PRA-08W-2C-Y-Z | 1 | 350 | 08W-2 | ||||||
![]() |
Standard direct-acting, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRB-8A-2D-Y-Z | 1 | 350 | 8A-2 |
PRB-8A-2C-Y-Z | 1 | 350 | 8A-2 | ||||||
PRB-08W-2C-Y-Z | 1 | 350 | 08W-2 | ||||||
![]() |
Proportional amplifier (PWM) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PCB-2600 | - | - | - |
PCB-2600C | - | - | - | ||||||
![]() |
Pilot-operated reducing | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PB-163A-30-Y-Z | 20 | 350 | 163A-3 |
PB-11A-X-Y-Z | 40 | 350 | 11A-3 | ||||||
PB-2A-X-Y-Z | 80 | 350 | 2A-3 | ||||||
PB-17A-X-Y-Z | 160 | 350 | 17A-3 | ||||||
PB-19A-X-Y-Z | 320 | 350 | 19A-3 | ||||||
![]() |
Pilot-operated reducing, main stage with integral 8A control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PB-11A-30-Y-8 | 40 | 350 | 11A-3 |
PB-2A-30-Y-8 | 80 | 350 | 2A-3 | ||||||
PB-17A-30-Y-8 | 160 | 350 | 17A-3 | ||||||
PB-19A-30-Y-8 | 320 | 350 | 19A-3 | ||||||
![]() |
Restrictive compensator, direct-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PD-163A-3J-Y-Z | 20 | 350 | 163A-3 |
PD-11A-3J-Y-Z | 40 | 350 | 11A-3 | ||||||
PD-2A-3J-Y-Z | 80 | 350 | 2A-3 | ||||||
PD-17A-3J-Y-Z | 160 | 350 | 17A-3 | ||||||
PD-19A-3J-Y-Z | 320 | 350 | 19A-3 | ||||||
![]() |
Poppet, direct-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PF-11A-3J-Y-Z | 30 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPC-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, low leakage, pressure Reducing/Relieving Valve, improved dynamic response, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPC-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, low leakage, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 |
![]() |
Pilot-operated, standard balanced, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPQ-10WA-4C-Y-Z-B1 | 30 | 350 | 10WA-4 |
![]() |
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74-3 | 20 | 350 | 11A-3 |