Cartridge Valves
FILTER
Directional Control
| Symbol | Description | ||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Piloted, 3-way 2-position, spool, internal vent | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DD-10W-42-Y-N | 38 | 240 | 10W-4 |
|
Piloted, 3-way 2-position, spool, port 3 to port 2, shift port 3 to port 4 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DD-12WH-5S-Y-Z | 80 | 240 | 12WH-5 |
|
Piloted, 3-way 2-position, spool, port 3 to port 2, shift port 3 to port 4 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DD-14WA-5E-Y-Z | 160 | 350 | 14WA-5 |
|
3-way 2-position, pilot-to-shift | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DD-52A-6A-Y-Z | 80 | 350 | 52A-6 |
|
Direct-acting, 3-way 2-position, port 2 to port 3, shift port 1 to port 2, drain | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DD-22A-4Q-Y-Z | 60 | 350 | 22A-4 |
|
Pilot-operated, 3-way 2-position, with drain to port 4 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DP-21A-4Q-Y-Z | 28 | 350 | 21A-4 |
| DP-22A-4Q-Y-Z | 60 | 350 | 22A-4 | ||||||
|
Pilot-operated, 3-way 2-position, with drain to port 4, normally open | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DP-22A-4M-Y-Z | 60 | 350 | 22A-4 |
|
Pilot-operated, 3-way 2-position, with drain to port 4, normally closed | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DP-22A-4N-Y-Z | 60 | 350 | 22A-4 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 2 and port 3 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DT-11A-3A-14-Z | 45 | 350 | 11A-3 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 1 and port 3 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DT-9A-3A-11-Z | 1 | 350 | 9A-3 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 2 and port 3 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DT-11A-3A-53-Z | 30 | 350 | 11A-3 |
|
Manual rotary, 3-way, 2-position, 0° - 90° | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DR-10W-3A-13-Z | 38 | 240 | 10W-3 |
|
Manual rotary, 4-way 2-position | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DR-10W-4A-10-Z | 11 | 240 | 10W-4 |
|
Manual rotary, 4-way 3-position, blocked center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DR-10W-4B-22-Z | 11 | 240 | 10W-4 |
|
4-way 2-position, spool, pilot-to-shift | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-61A-6E-10-Z | 28-40 | 350 | 61A-6 |
| DC-62A-6E-10-Z | 38-120 | 350 | 62A-6 | ||||||
|
4-way 2-position, spool, pilot-to-shift | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-62A-6E-18-Z | 38-120 | 350 | 62A-6 |
| DC-63A-6E-18-Z | 95-380 | 350 | 63A-6 | ||||||
| DC-64A-6E-18-Z | 200-760 | 350 | 64A-6 | ||||||
|
4-way 3-position, spool, pilot-to-shift, blocked center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-61A-6E-22-Z | 28-40 | 350 | 61A-6 |
| DC-62A-6E-22-Z | 38-120 | 350 | 62A-6 | ||||||
| DC-63A-6E-22-Z | 95-380 | 350 | 63A-6 | ||||||
| DC-64A-6E-22-Z | 200-760 | 350 | 64A-6 | ||||||
|
4-way 3-position, spool, pilot-to-shift, open center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-61A-6E-23-Z | 28-40 | 350 | 61A-6 |
| DC-62A-6E-23-Z | 38-120 | 350 | 62A-6 | ||||||
| DC-63A-6E-23-Z | 95-380 | 350 | 63A-6 | ||||||
| DC-64A-6E-23-Z | 200-760 | 350 | 64A-6 | ||||||
|
4-way 3-position, spool, pilot-to-shift, floating center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-61A-6E-24-Z | 28-40 | 350 | 61A-6 |
| DC-62A-6E-24-Z | 38-120 | 350 | 62A-6 | ||||||
| DC-63A-6E-24-Z | 95-380 | 350 | 63A-6 | ||||||
| DC-64A-6E-24-Z | 200-760 | 350 | 64A-6 | ||||||
|
4-way 3-position, spool, pilot-to-shift, tandem centre | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DC-61A-6E-26-Z | 28-40 | 350 | 61A-6 |
| DC-63A-6E-26-Z | 95-380 | 350 | 63A-6 | ||||||
| DC-64A-6E-26-Z | 200-760 | 350 | 64A-6 |