Restrictive, maximum setting 280 bar Main Code Flow(l/min) Pressure(bar) Cavity CB-11A-X-Y-Z20 20 280 11A-3
CB-2A-3C-Y-Z32 32 280 2A-3
CB-17A-3C-Y-Z60 60 280 17A-3
CB-19A-3C-Y-Z80 80 280 19A-3
Restrictive, maximum setting 350 bar Main Code Flow(l/min) Pressure(bar) Cavity CB-11A-X-Y-Z20 20 350 11A-3
CB-2A-3D-Y-Z32 32 350 2A-3
CB-17A-3D-Y-Z60 60 350 17A-3
CB-19A-3D-Y-Z80 80 350 19A-3
Ultra-restrictive, maximum setting 280 bar Main Code Flow(l/min) Pressure(bar) Cavity CB-11A-X-Y-Z10 10 280 11A-3
Ultra-restrictive, maximum setting 350 bar Main Code Flow(l/min) Pressure(bar) Cavity CB-11A-X-Y-Z10 10 350 11A-3
Pilot assisted relief with check Main Code Flow(l/min) Pressure(bar) Cavity CB-16WC-33-Y-Z 200 350 16WC-3
Fixed orifice, pressure compensated, with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity FR-162A-2C-Y-Z 0.4-11 350 162A-2
FR-13A-2C-Y-Z 0.4-23 350 13A-2
FR-16A-2C-Y-Z 0.8-95 350 16A-2
Fixed orifice, pressure compensated Main Code Flow(l/min) Pressure(bar) Cavity FR-13A-2F-Y-Z-1 10 10-350 13A-2
FR-08W-X-Y-Z 12 240 08W-2
FR-13A-2F-Y-Z 0.4-23 10-350 13A-2
FR-10W-20-Y-Z 23 240 10W-2
FR-5A-2F-Y-Z 0.4-45 10-350 5A-2
FR-16A-2F-Y-Z 0.8-95 10-350 16A-2
FR-16W-2F-Y-Z 120 350 16W-2
FR-33MC-2F-Y-Z 120 350 33MC-2
FR-18A-2F-Y-Z 1-200 10-350 18A-2
Fixed orifice, pressure compensated Main Code Flow(l/min) Pressure(bar) Cavity FR-08W-22-Y-Z 20 350 08W-2
FR-10W-22-Y-Z 40 350 10W-2
Fully adjustable pressure compensated flow control valve with reverse flow check and sharp-edge orifice Main Code Flow(l/min) Pressure(bar) Cavity FR-13A-20-Y-Z 23 350 13A-2
FR-20MC-20-Y-Z 23 350 20MC-2
FR-5A-20-Y-Z 45 350 5A-2
FR-16A-20-Y-Z 95 350 16A-2
FR-18A-20-Y-Z 200 350 18A-2
Fully adjustable needle with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity NC-162A-21-Y-Z 15 350 162A-2
NC-20MC-21-Y-Z 30 350 20MC-2
Fully adjustable needle with reverse flow check and sharp-edge orifice Main Code Flow(l/min) Pressure(bar) Cavity NC-13A-21-Y-Z 25 350 13A-2
NC-5A-21-Y-Z 50 350 5A-2
NC-16A-21-Y-Z 120 350 16A-2
NC-18A-21-Y-Z 210 350 18A-2
Fixed orifice non-pressure compensated with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity NC-08W-20-Y-N-Z 30 350 08W-2
NC-08W-22-Y-N-Z 30 350 08W-2
NC-10W-20-Y-N-Z 60 350 10W-2
NC-10W-22-Y-N-Z 60 350 10W-2
Fixed orifice, non-pressure compensated, with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity NC-162A-21-Y-N-Z 30 350 162A-2
Fully adjustable needle with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity NC-08W-20-Y-Z 35 350 08W-2
NC-10W-20-Y-Z 45 350 10W-2
NC-12W-20-Y-Z 120 350 12W-2
NC-16W-20-Y-Z 150 350 16W-2
NC-21E-20-Y-Z 150 350 21E-2
Fully adjustable needle, pilot capacity Main Code Flow(l/min) Pressure(bar) Cavity NF-8A-20-Y-Z 0.8 350 8A-2
Fully adjustable needle, compact design Main Code Flow(l/min) Pressure(bar) Cavity NV-162A-X-Y-Z 15 350 162A-2
Fixed orifice Main Code Flow(l/min) Pressure(bar) Cavity NV-162A-2F-Y-Z 15 350 162A-2
Fully adjustable needle with sharp-edge orifice Main Code Flow(l/min) Pressure(bar) Cavity NV-13A-20-Y-Z 25 350 13A-2
NV-5A-20-Y-Z 50 350 5A-2
NV-16A-20-Y-Z 100 350 16A-2
NV-18A-20-Y-Z 240 350 18A-2
Fully adjustable needle Main Code Flow(l/min) Pressure(bar) Cavity NV-08W-20-Y-Z 36 350 08W-2
NV-20M-20-Y-Z 40 350 20M-2
NV-10W-20-Y-Z 50 350 10W-2
NV-17E-20-Y-Z 58 350 17E-2
NV-12W-20-Y-Z 126 350 12W-2
NV-21E-20-Y-Z 126 350 21E-2
NV-16W-20-Y-Z 150 350 16W-2
Fully adjustable needle with low noise and sharp-edge orifice Main Code Flow(l/min) Pressure(bar) Cavity NV-10W-20-67-Z 50 350 10W-2