Symbol |
Description |
|
Pilot-operated, 3-way 2-position, with drain to port 4 |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DP-21A-4Q-Y-Z |
28 |
350 |
21A-4 |
DP-22A-4Q-Y-Z |
60 |
350 |
22A-4 |
|
Pilot-operated, 3-way 2-position, with drain to port 4, normally open |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DP-22A-4M-Y-Z |
60 |
350 |
22A-4 |
|
Pilot-operated, 3-way 2-position, with drain to port 4, normally closed |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DP-22A-4N-Y-Z |
60 |
350 |
22A-4 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 2 and port 3 |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DT-11A-3A-14-Z |
45 |
350 |
11A-3 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 1 and port 3 |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DT-9A-3A-11-Z |
1 |
350 |
9A-3 |
|
Direct-acting, 3-way, 2-position, manual operation, flow between port 2 and port 3 |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
DT-11A-3A-53-Z |
30 |
350 |
11A-3 |
|
Vented, atmospherically referenced, without relief function |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
CA-11A-3N-Y-Z |
60 |
350 |
11A-3 |
CA-2A-3N-Y-Z |
120 |
350 |
2A-3 |
|
Without relief function |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
MB-2A-3N-Y-Z |
120 |
350 |
2A-3 |
MB-17A-3N-Y-Z |
240 |
350 |
17A-3 |
MB-19A-3N-Y-Z |
480 |
350 |
19A-3 |
|
Vented, without relief function |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
MW-22A-4N-Y-Z |
120 |
350 |
22A-4 |
MW-23A-4N-Y-Z |
240 |
350 |
23A-4 |
MW-24A-4N-Y-Z |
480 |
350 |
24A-4 |
|
Vented, without relief function |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
CW-21A-4N-Y-Z |
60 |
350 |
21A-4 |
CW-20WS-4N-Y-Z |
300 |
400 |
20WS-4 |
|
Pilot-to-open, normally closed, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LB-21A-4S-Y-Z |
60 |
350 |
21A-4 |
LB-22A-4S-Y-Z |
120 |
350 |
22A-4 |
LB-23A-4S-Y-Z |
240 |
350 |
23A-4 |
LB-24A-4S-Y-Z |
480 |
350 |
24A-4 |
|
Normally closed, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LB-21A-4P-Y-Z |
60 |
350 |
21A-4 |
LB-22A-4P-Y-Z |
120 |
350 |
22A-4 |
LB-24A-4P-Y-Z |
480 |
350 |
24A-4 |
|
Normally closed, balanced poppet, vent-to-open, logic element with Integral 08W-2 / 8A-2 control cavity |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LB-23A-4R-Y-Z |
240 |
350 |
23A-4 |
LB-24A-4R-Y-Z |
480 |
350 |
24A-4 |
|
Pilot-to-closed, normally open, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LN-21A-4S-Y-Z |
60 |
350 |
21A-4 |
LN-22A-4S-Y-Z |
120 |
350 |
22A-4 |
LN-23A-4S-Y-Z |
240 |
350 |
23A-4 |
LN-24A-4S-Y-Z |
480 |
350 |
24A-4 |
|
Normally open, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LN-21A-4P-Y-Z |
60 |
350 |
21A-4 |
LN-22A-4P-Y-Z |
120 |
350 |
22A-4 |
|
Bypass/restrictive, priority modulating element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LR-10W-40-Y-Z |
38 |
240 |
10W-4 |
LR-12W-40-Y-Z |
80 |
240 |
12W-4 |
LR-16W-40-Y-Z |
100 |
240 |
16W-4 |
|
Bypass/restrictive, priority modulating element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LR-31A-41-Y-Z |
60 |
350 |
31A-4 |
LR-32A-41-Y-Z |
120 |
350 |
32A-4 |
LR-33A-41-Y-Z |
240 |
350 |
33A-4 |
|
Normally closed, vent-to-open, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LB-22A-4R-Y-Z |
120 |
350 |
22A-4 |
|
Normally closed, pilot-to-open, balanced poppet, logic element |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
LB-27MA-4S-Y-Z |
90 |
350 |
27MA-4 |
|
Direct-acting, external drain |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PD-21A-40-Y-Z |
40 |
350 |
21A-4 |
PD-22A-40-Y-Z |
80 |
350 |
22A-4 |