Electro-Proportional Valves
FILTER
Electro-Proportional Valves
| Symbol | Description | ||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Unbalanced poppet, vent-to-open, switching element, main-stage with integral 08W-2 / 8A-2 control cavity (spring biased closed, pilot source from port 2) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LO-11A-3B-Y-8 | 95 | 350 | 11A-3 |
| LO-2A-3B-Y-8 | 200 | 350 | 2A-3 | ||||||
| LO-17A-3B-Y-8 | 380 | 350 | 17A-3 | ||||||
| LO-19A-3B-Y-8 | 760 | 350 | 19A-3 | ||||||
|
Unbalanced poppet, vent-to-open, switching element, main-stage with integral 08W-2 / 8A-2 control cavity (spring biased closed, higher of ports 1 or 2 pilot source) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LO-11A-3D-Y-8 | 95 | 350 | 11A-3 |
| LO-2A-3D-Y-8 | 200 | 350 | 2A-3 | ||||||
| LO-17A-3D-Y-8 | 380 | 350 | 17A-3 | ||||||
| LO-19A-3D-Y-8 | 760 | 350 | 19A-3 | ||||||
|
Normally closed, balanced poppet, vent-to-open, logic element with Integral 08W-2 / 8A-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-23A-4R-Y-Z | 240 | 350 | 23A-4 |
| LB-24A-4R-Y-Z | 480 | 350 | 24A-4 | ||||||
|
2-way, pilot shifted, normally closed, proportional throttle | Main Code | Flow(l/min) | Pressure(bar) | Cavity | FP-24A-4C-Y-Z | 240 | 350 | 24A-4 |
|
Normally closed, electro-proportional, pressure compensated | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFT-12W-3G-Y-Z | 50 | 240 | 12W-3 |
|
Ventable, pilot-operated, balanced poppet, main stage with integral 8A-2/08W-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | RV-2A-3G-Y-Z | 120 | 350 | 2A-3 |
| RV-17A-3G-Y-Z | 240 | 350 | 17A-3 | ||||||
| RV-19A-3G-Y-Z | 480 | 350 | 19A-3 | ||||||
|
Ventable, balanced piston relief, main stage with integral 8A-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | RV-11A-30-Y-8 | 60 | 350 | 11A-3 |
| RV-2A-30-Y-8 | 120 | 350 | 2A-3 | ||||||
| RV-17A-30-Y-8 | 240 | 350 | 17A-3 | ||||||
| RV-19A-30-Y-8 | 480 | 350 | 19A-3 | ||||||
|
Ventable, pilot-operated, balanced piston with external drain with integral 8A control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | RV-21A-40-Y-8 | 60 | 350 | 21A-4 |
| RV-22A-40-Y-8 | 120 | 350 | 22A-4 | ||||||
| RV-23A-40-Y-8 | 240 | 350 | 23A-4 | ||||||
|
Electro-proportional, normally closed, spool | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PEA-12W-3G-Y-Z | 80 | 240 | 12W-3 |
|
Pilot-operated inverse balanced, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRP-08W-2C-Y-Z-A1 | 30 | 240 | 08W-2 |
| PRP-10W-2C-Y-Z-A1 | 95 | 350 | 10W-2 | ||||||
|
4-way 3-position, blocked center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PES-10W-4C-22-N-Z | 22 | 250 | 10W-4 |
|
4-way 3-position, A and B to T center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PES-10W-4C-24-N-Z | 22 | 250 | 10W-4 |
|
Pilot-operated, balanced piston relief valve, main stage with integral 8A-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | RP-12W-26-Y-8 | 200 | 350 | 12W-2 |
| RP-16W-26-Y-8 | 300 | 350 | 16W-2 | ||||||
| RP-33MC-26-Y-8 | 300 | 350 | 33MC-2 | ||||||
|
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74-3 | 20 | 350 | 11A-3 |
|
Ventable, pilot-operated, balanced poppet, main stage with integral 8A-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | RV-11A-3G-Y-8 | 60 | 350 | 11A-3 |
|
Proportional amplifier (PWM) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PCB-2600 | - | - | - |
| PCB-2600C | - | - | - |