Pagination:
| Symbol | Description | ||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Pilot-operated, flow port 1 to port 2, port 1 blocked when energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-20M-2A-10-Z-05 | 40 | 350 | 20M-2 |
| EP-22M-2A-10-Z-05 | 70 | 350 | 22M-2 | ||||||
| EP-27M-2A-10-Z-05 | 150 | 350 | 27M-2 | ||||||
| EP-35MV-2A-10-Z-05 | 150 | 350 | 35MV-2 | ||||||
|
Pilot-operated, port 2 blocked, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-08W-2A-05-Z-85 | 40 | 350 | 08W-2 |
| EP-10W-2A-05-Z-85 | 70 | 350 | 10W-2 | ||||||
| EP-12W-2A-05-Z-85 | 150 | 350 | 12W-2 | ||||||
| EP-16W-2A-05-Z-85 | 150 | 350 | 16W-2 | ||||||
|
Pilot-operated, port 2 blocked, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-17E-2A-05-Z-85 | 70 | 350 | 17E-2 |
| EP-21E-2A-05-Z-85 | 150 | 350 | 21E-2 | ||||||
|
Pilot-operated, port 2 blocked, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-22ML-2A-05-Z-85 | 70 | 350 | 22ML-2 |
| EP-27M-2A-05-Z-85 | 150 | 350 | 27M-2 | ||||||
|
Pilot-operated, flow port 1 to port 2, port 1 blocked when energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-16W-2A-10-Z-95 | 240 | 350 | 16W-2 |
|
Pilot-operated, flow port 1 to port 2, port 1 blocked when energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-16A-2A-10-Z-95 | 240 | 350 | 16A-2 |
| EP-18A-2A-10-Z-95 | 480 | 350 | 18A-2 | ||||||
|
Pilot-operated, flow port 1 to port 2, port 1 blocked when energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-21E-2A-10-Z-95 | 240 | 350 | 21E-2 |
|
Unbalanced poppet, pilot-to-close, spring biased closed, with position switch | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LOS-2A-3C-Y-Z | 200 | 350 | 2A-3 |
|
Bypass/restrictive, priority modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-10W-40-Y-Z | 38 | 240 | 10W-4 |
| LR-12W-40-Y-Z | 80 | 240 | 12W-4 | ||||||
| LR-16W-40-Y-Z | 100 | 240 | 16W-4 | ||||||
|
Spool type, normally closed, modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-11A-36-Y-Z | 6 | 350 | 11A-3 |
|
Spool type, normally closed modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-12WS-30-Y-Z | 150 | 350 | 12WS-3 |
|
Pilot-operated, port 2 blocked, bidirectional flow energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-16W-2A-05-Z-95 | 240 | 350 | 16W-2 |
| EP-20W-2A-05-Z-95 | 300 | 350 | 20W-2 (20WB-2) | ||||||
|
Pilot-operated, port 2 blocked, bidirectional flow energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-16A-2A-05-Z-95 | 240 | 350 | 16A-2 |
| EP-18A-2A-05-Z-95 | 480 | 350 | 18A-2 | ||||||
|
Pilot-operated, port 2 blocked, bidirectional flow energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-21E-2A-05-Z-95 | 240 | 350 | 21E-2 |
|
Pilot-operated, port 2 blocked, bidirectional flow energized, high flow | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-42M-2A-05-Z-95 | 300 | 350 | 42M-2 |
|
Pilot-operated, flow port 2 to port 1, bidirectional flow blocked when energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-19E-2A-12-Z-05 | 40 | 350 | 19E-2 |
| EP-17E-2A-12-Z-05 | 70 | 350 | 17E-2 | ||||||
| EP-21E-2A-12-Z-05 | 150 | 350 | 21E-2 | ||||||
|
Pilot-operated, flow port 2 to port 1, bidirectional flow blocked when energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-35MV-2A-12-Z-05 | 150 | 350 | 35MV-2 |
|
Inverse direct-acting, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRA-8A-2D-Y-Z-74 | 1 | 350 | 8A-2 |
| PRA-8A-2C-Y-Z | 1 | 350 | 8A-2 | ||||||
| PRA-08W-2C-Y-Z | 1 | 350 | 08W-2 | ||||||
|
Standard direct-acting, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRB-8A-2D-Y-Z | 1 | 350 | 8A-2 |
| PRB-8A-2C-Y-Z | 1 | 350 | 8A-2 | ||||||
| PRB-08W-2C-Y-Z | 1 | 350 | 08W-2 | ||||||
|
Pilot-operated with filter, port 2 blocked, flow port 2 to port 1 energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-08W-2A-07-Z-04 | 30 | 350 | 08W-2 |
| EP-08W-2H-07-Z-04 | 30 | 350 | 08W-2 | ||||||
| EP-08W-2A-07-Z-05 | 40 | 350 | 08W-2 |
- Home