Cartridge Valves
Filter By
Cavity
(131)
(77)
(70)
(87)
(8)
(9)
(4)
(5)
(3)
(7)
(3)
(28)
(30)
(22)
(3)
(19)
(1)
(28)
(26)
(8)
(7)
(6)
(9)
(7)
(16)
(12)
(3)
(5)
(10)
(8)
(6)
(5)
(2)
(2)
(2)
(28)
(8)
(12)
(3)
(20)
(2)
(17)
(18)
(14)
(3)
(2)
(1)
(1)
(3)
(1)
(5)
(1)
(1)
(14)
(2)
(1)
(3)
(1)
(1)
(1)
(8)
(2)
(18)
(1)
(1)
(9)
(3)
(1)
(5)
(1)
(1)
(1)
(12)
(2)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Flow(l/min)
(55)
(124)
(76)
(72)
(95)
(23)
(36)
(5)
(40)
(20)
(7)
(7)
(14)
(5)
(7)
(5)
(8)
(6)
(7)
(10)
(2)
(5)
(11)
(2)
(16)
(3)
(6)
(6)
(2)
(1)
(8)
(2)
(1)
(1)
(5)
(1)
(2)
(2)
(5)
(26)
(27)
(3)
(1)
(1)
(1)
(1)
(1)
(2)
(1)
(1)
(1)
(5)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(4)
(1)
(2)
(1)
(4)
(6)
(6)
(3)
(1)
(3)
(1)
(1)
(3)
(3)
(3)
(3)
(1)
(15)
(16)
(5)
(1)
(2)
(2)
(1)
(1)
(1)
(1)
(3)
(2)
(1)
(1)
(1)
(1)
(1)
(1)
Pressure(bar)
(31)
(304)
(20)
(1)
(29)
(1)
(4)
(2)
(1)
(5)
(4)
(1)
(1)
Pilot Ratio
(14)
(13)
(6)
(5)
(3)
(7)
(5)
(3)
(2)
(7)
(5)
(1)
(1)
FILTER

Cartridge Valves

Pagination:
Symbol Description
Pilot-operated reducing/relieving Main Code Flow(l/min) Pressure(bar) Cavity PP-163A-X-Y-Z 20 350 163A-3
PP-10W-X-Y-Z 40 350 10W-3
PP-11A-X-Y-Z 40 350 11A-3
PP-2A-X-Y-Z 80 350 2A-3
PP-17A-X-Y-Z 160 350 17A-3
PP-19A-X-Y-Z 320 350 19A-3
Pilot-operated, pressure reducing/relieving main stage with integral 8A control cavity Main Code Flow(l/min) Pressure(bar) Cavity PP-11A-X-Y-8 40 350 11A-3
PP-2A-X-Y-8 80 350 2A-3
PP-17A-X-Y-8 160 350 17A-3
PP-19A-X-Y-8 320 350 19A-3
Reducing valve with thermal relief, direct-acting, poppet type Main Code Flow(l/min) Pressure(bar) Cavity PG-11A-30-Y-Z 30 350 11A-3
Pilot-operated standard balanced, low pressure with no command Main Code Flow(l/min) Pressure(bar) Cavity PPP-08W-3C-Y-Z-B1 30 350 08W-3
PPP-10W-3C-Y-Z-B 40 350 10W-3
Atmospherically referenced, direct-acting with reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity SC-13A-20-Y-Z 60 350 13A-2
SC-13A-20-Y-Z-1 60 350 13A-2
SC-5A-20-Y-Z 120 350 5A-2
Atmospherically referenced, direct-acting without reverse flow check Main Code Flow(l/min) Pressure(bar) Cavity SD-13A-20-Y-Z 60 350 13A-2
Pilot-operated, 3-way 2-position, with internal drain to port 3, normally closed Main Code Flow(l/min) Pressure(bar) Cavity DP-11A-3N-Y-Z 28 350 11A-3
DP-2A-3N-Y-Z 60 350 2A-3
Pilot-operated, 3-way 2-position, with internal drain to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DP-11A-3Q-Y-Z 28 350 11A-3
DP-2A-3Q-Y-Z 60 350 2A-3
Pilot-operated, 3-way 2-position, with internal drain to port 3, normally open Main Code Flow(l/min) Pressure(bar) Cavity DP-11A-3M-Y-Z 28 350 11A-3
DP-2A-3M-Y-Z 60 350 2A-3
Pilot-operated, 3-way 2-position, with internal drain to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DP-2A-3P-Y-Z 60 350 2A-3
Direct-acting, 3-way 2-position, port 2 to port 3, shift port 1 to port 2, internal drain Main Code Flow(l/min) Pressure(bar) Cavity DD-11A-3Q-Y-Z 28 350 11A-3
DD-2A-3Q-Y-Z 60 350 2A-3
3-way, 2-position, direct acting, normally closed, shift port 2 to port 3, internal drain Main Code Flow(l/min) Pressure(bar) Cavity DD-11A-3N-Y-Z 28 350 11A-3
Manual rotary, 3-way, 2-position, 0° - 90° Main Code Flow(l/min) Pressure(bar) Cavity DR-10W-3A-11-Z 38 240 10W-3
Direct-acting, 3-way 2-position, port 3 to port 4, shift port 2 to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DD-21A-4R-Y-Z 28 350 21A-4
Direct-acting, 3-way 2-position, normally closed, shift port 2 to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DD-21A-4N-Y-Z 28 350 21A-4
Piloted, 3-way 2-position, spool, vented, atmospherically referenced Main Code Flow(l/min) Pressure(bar) Cavity DD-10W-4S-Y-Z 38 240 10W-4
DD-12W-4S-Y-Z 80 240 12W-4
DD-16W-4S-Y-Z 170 240 16W-4
3-way 2-position, vent to shift Main Code Flow(l/min) Pressure(bar) Cavity DQ-31A-40-Y-Z 60 350 31A-4
DQ-32A-40-Y-Z 120 350 32A-4
DQ-33A-40-Y-Z 240 350 33A-4
DQ-34A-40-Y-Z 480 350 34A-4
3-way 2-position, vent to shift Main Code Flow(l/min) Pressure(bar) Cavity DQ-31A-41-Y-Z 60 350 31A-4
DQ-32A-41-Y-Z 120 350 32A-4
DQ-33A-41-Y-Z 240 350 33A-4
DQ-34A-41-Y-Z 480 350 34A-4
Piloted, 3-way 2-position, spool, internal vent Main Code Flow(l/min) Pressure(bar) Cavity DD-10W-42-Y-N 38 240 10W-4
Piloted, 3-way 2-position, spool, port 3 to port 2, shift port 3 to port 4 Main Code Flow(l/min) Pressure(bar) Cavity DD-12WH-5S-Y-Z 80 240 12WH-5
« 1 2 3 4 5 6 7 8 9 10 »